1 2 3 4
Skill Support
The external detecting of solar PV modules circuit:
Some of engineers use the turn-key solar cell test equipment, such as devices using a solar simulator, which is a standardized light source, can be used to control the light energy into the solar cell. 

However, if a very large solar or modules, solar simulator will be unable to produce adequate light.   For example: measured solar module may be is a part of the solar collection system in the outdoor. In 

this case, the test will be the sun itself the only practical light source available. Since, in the outdoors is virtually impossible to transport without a turn-key solar simulator test system, so this test 

will need to use the improvements made by the standard test equipment solutions for some other tests to perform.   Another concern in outdoor is “temperature”. Because the battery performance will be 

affected by temperature, therefore, needs to monitor temperature in the test, the battery performance is not only dependent on the temperature, and the test device's performance also depends on 

temperature.Most of equipment suppliers and their equipment did not indicate at room temperature in a very narrow temperature range (ex: +25 ℃ ± 5 ℃) than the performance of other vendors will provide a 

temperature coefficient specifications, able to adjust the test equipment accuracy range to target operating at its specified operating temperature range to be corrected.For higher power test load   For 

high power applications, the standard electronic load for testing solar cells, many engineers do not think of using electronic load to test solar cells, because they are accustomed to using a turn-key 

system or four-quadrant power supply.   Considering the solar cell will generate energy when using a four-quadrant power supply to test it, the power of the actual operating modes are: the power supply 

terminals of the solar cell by applying a positive voltage, while the current flows from the solar cell of the four-quadrant power supply terminal, this means that the four-quadrant power supply reverse 

current (in terms of its terminals). In these conditions, can also be called four-quadrant power supply is a "Power sink."   Electrically speaking, there is a positive voltage across Canada and has the 

power flow (there is the reverse current) instrument is called electronic load. Therefore, for most light irradiation and the energy of the solar cell can produce a solar cell test, the four-quadrant power 

actually plays the role of the electronic load.   Advantage of using an electronic load, this load can be used in a variety of current Khan Power level. Watts is up to 50 watts and hundreds of thousands of 

watts amp electronic load, you can easily overcome the four-quadrant power brought 3A, 20-watt limit.   
Electronic load in constant voltage mode is also known as CV mode. In the CV mode, the load can be adjusted by the current flowing through its own, and adjusted the voltage across it to maintain a constant 

voltage value. Thus, CV mode can be used to create a voltage sweep, with the load to control the output voltage of the solar cell, and then measuring the resulting current.


Article From http://www.bangtest-china.net            Author Bang Instrument co.,ltd